  Datasheet File OCR Text:
  series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 1 of 7 north america only features: ? wide 2:1 input range ? efficiency up to 92% ? adjustable single output voltage ? remote on/off function ? undervoltage lockout ? soft start ? high power density models single output model input voltage (v) output voltage (v) output current max ( a) maximum capacitive load (f) efficiency (%) am40e - 1203sz 9 - 18 3.3 8 21800 90 am40e - 1205sz 9 - 18 5 8 13600 91 am40e - 1212sz 9 - 18 12 3.33 2300 91 am40e - 1215sz 9 - 18 15 2.6 7 1500 91 am40e - 2403sz 18 - 36 3.3 8 21800 91 am40e - 2405sz 18 - 36 5 8 13600 92 am 40e - 2412sz 18 - 36 12 3.33 2300 91 am40e - 2415sz 18 - 36 15 2.6 7 1500 92 am40e - 4803sz 36 - 75 3.3 8 21800 91 am40e - 4805sz 36 - 75 5 8 13600 92 am40e - 4812sz 36 - 75 12 3.33 2300 91 am40e - 4815sz 36 - 75 15 2.6 7 1500 92 models dual output model input voltage (v) ou tput voltage (v) output current max ( a) maximum capacitive load (f) efficiency (%) am40e - 1212dz 9 - 18 12 1.6 7 1200 91 am40e - 1215dz 9 - 18 15 1.33 750 92 am40e - 2412dz 18 - 36 12 1.6 7 1200 91 am40e - 2415dz 18 - 36 15 1.33 750 92 am40e - 4812dz 36 - 75 12 1.6 7 1200 92 am40e - 4815dz 36 - 75 15 1.33 750 92 note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifica tions parameters nominal typical maximum units voltage range 12 9 - 18 vdc 24 18 - 36 48 36 - 75 filter (pi) network start up time 30 ms absolute maximum rating 12 25 vdc 24 50 48 100 peak input voltage time 1 s on/off c ontrol on: 3 ~12vdc or open circuit ; off C 0 ~ 1.2vdc or short circuit between pin 2 and pin 3 (off idle current: 5ma typical)
series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 2 of 7 north america only input specifications ( continued) parameters nominal typical maximum units under voltage lockout 12v on/off 8.6 / 7.9 vdc 24v on/off 17.8 / 16 48v on/off 33.5 / 30.5 input reflected ripple current 20 ma p - p isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec 1600 vdc case/input and output 3 sec 1600 vdc resistance < 1000 mohm capacitance 1000 pf output specifications parameters conditions typical maximum units voltage accuracy 1 % cross regulation (dual output models) 25% load on one output 100% load on second load 5 % over voltage protection zener diode clamp over load protection 130 % of iout short circuit protection continuous short circuit restart auto - recovery li ne voltage regulation hl - ll 0.5 % load voltage regulation (single) 0% to 100% load 0.5 % load voltage regulation (dual) 0% to 100% load 1 % temperature coefficient 0.02 %/ o c ripple & noise ( 20mhz bandwidth) 3.3vout/5vout other models 100 15 0 mv p -p voltage adjustment range (single) 10 % minimum load current 0 % of max general specifications parameters conditions typical maximum units switching frequency 100% load 270 khz operating temperature derating above 5 5 - 40 to +71 o c st orage temperature - 40 to +125 o c maximum case temperature 105 o c derating 2 .5 %/ o c cooling free air convection humidity 95 % rh case material nickel coated copper weight 32 g dimensions (l x w x h) 2.00 x 1.00 x 0.40 inches 50.80 x 25.4 0 x 10.16 mm mtbf >328,000 hrs (mil - hdbk - 217f, ground benign, t=+25 o c) hours maximum soldering temperature 1.5mm from case for 10 sec 260 o c transient recovery time 250 s transient recovery deviation 3 %
series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 3 of 7 north america only safety specifications parameter s agency approval ce safety en55022 : 2006 + a1:2007, class b iec61000 - 3 - 2:2006+a2:2009 iec61000 - 3 - 3:2008 en55024 :1998 + a1:2001 + a2:2003 iec61000 - 4 - 2: 2008 iec61000 - 4 - 3 :2006+a1: 2007 iec61000 - 4 -4 :2004 iec61000 - 4 - 5 :2005 iec61000 - 4 - 6 :200 8 iec61000 - 4 - 8 :2009 note: also designed to meet iec 60950 - 1:2001 pin out specifications pin single dual 1 + v input + v input 2 - v input - v input 3 on/off control on/off control 4 + v output + v output 5 - v output common 6 trim - v output dimensions 1 2 3 2.54 (0.10) 5.08 (0.20) 10.16 (0.40) 50.80 (2.00) 25.40 (1.00) bottom view 2.54 (0.10) 2.54 (0.10) 10.16 (0.40) 10.16 (0.40) 10.16 (0.40) 5.08 (0.20) single and dual output models 5.08 (0.20) 4 5 6 notes: all dimensions are typical in millimeters (inches ). pin pitch tolerance 0.35 (0.014) case tolerance 0.50 (0.02)
series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 4 of 7 north america only trimming derating - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 safe operating area output power (%) ambient temperature o c 71 55
series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 5 of 7 north america only input reflected ripple current test step dc power source cin dc/dc converter +v input -v input +v output load -v output + - lin current probe input reflected ripple current is measured through a source inductor lin(4.7uh) and a source capacitor cin (47uf, esr<1.0ohm at 100khz) at a nominal input and full load output ripple and noise reduction cin dc/dc converter +v input -v input +v output load -v output 10uf dc power source cout 10uf 1uf to reduce ripple and noise, it is recommended to use a 1f ceramic disk capacitor and a 10f electrolytic + - contro l on/off pin connection example dc/ dc converter +v input -v input on/off control 6 7 4 5
series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 6 of 7 north america only emi filter load am40e-xxyz (single output) +vin -vin +vout -vout c1 c2 c3 c4 c5 c6 c9 c7 c8 l1 load am40e-xxyz (dual output) +vin -vin +vout -vout c1 c2 c3 c4 c5 c6 c8 c7 com l1
series am 40e -z 40 watt | dc - dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 051e r12.c 7 of 7 north america only eft/surge note: 1. datasheets are updated as needed and as such, specifications are subject to chang e without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. a imtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary and may not be available for relea se. 6. this product is not designed for u se in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applicat ions which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. warranty is in accorda nce with aimtecs standard terms of sale available at www.aimtec.com. model c1 l1 c2/c3/c5/c6 c4 c7 c8 c9 am40e - 12xxsz (single) 220 f, 100v common choke 68h 1812,6.8 f, 50v 330 f, 100v 1206,1000pf, 2kv am40e - 24xxsz (single) 220 f, 100v common choke 68h 1812,4.7f, 50v 220 f, 100v 1206,1000pf, 2kv 1206,1000pf, 2kv am40e - 48xxsz (single) 220 f, 100v common choke 68h 1812,1.5f, 50v 220 f, 100v 1206,1000pf, 2kv 1206,1000pf, 2kv am40e - 12xxdz (dual) 220 f, 100v common choke 68h 1812,6.8f, 50v 330 f, 100v 1206,1000pf, 2kv 1206,1000pf, 2kv am40e - 24xxdz (dual) 220 f, 100v common choke 68h 1812,4.7f, 50v 220 f, 100v 1206,1000pf, 2kv 1206,1000pf, 2kv am4 0e - 48xxdz (dual) 220 f, 100v common choke 68h 1812,1.5f, 50v 220 f, 100v 1206,1000pf, 2kv 1206,1000pf, 2kv c1 dc/ dc converter + v input - v input + v output load - v output 220uf 100v


▲Up To Search▲   

 
Price & Availability of AM40E-1203SZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X